Task Scheduler

The Task Scheduler section represents a list of all system utilities (see screenshot below) and is aimed at providing a possibility to manage and configure them as user desires. List of system utilities has the following structure:

Screenshot: Task Scheduler section

Image Removed

 Image Added

Column NameDescription
Active

Status of the utility. Depending on the icon, the status can be either Image Modified enabled or Image Modified disabled.

In order to

To change a utility status, click on the icon in the table.

Manual Run

Each utility is run with a certain periodicity, specified in the Run at column.

By

pressing

clicking the Run utilityImage Modifiedicon, you manually start this utility regardless of its Run at column value.

NameName of the utility. The full list of system utilities with their descriptions is provided in a table below
Run atPeriodicity at which each utility is run
In Queue
From
fromIf the utility is run manually, time and date when its launch was initiated will be specified in the column
Last RunTime and date when the last run was initiated


Utility NameDescription
Backup ManagerUtility that manages system backup processes
Balances ManagerCreates automatic charges
RADIUS ServerRADIUS server process
SIP Redirect ServerSIP Redirect server process
Cache ManagerCache Manager process whose main function is to
continuously
monitor and include client-related changes for RADIUS and SIP Redirect continuously
CalculatorUtility that processes all data collected from
CDR
xDR-files
Calling Card ManagerCalling Cards manager process
CleanerUtility that automatically cleans old messages
from 
from the Events Log section
Dynamic Routing ManagerUtility that creates routing tables used in Dynamic Routing feature
Email Rates ManagerUtility that imports rate tables updates from emails
Events ManagerProcess that sends events to
e-mails
emails according to Events Config
Provisioning ManagerUtility that processes
event
events asynchronously
Factors WatcherUtility that
controls 
controls the Factors Watcher tool
Files CollectorUtility that controls file collectors
Files DownloaderUtility that automatically downloads
cdr
xDR-files from switch host
Import ManagerUtility that performs data import
Invoicing ManagerUtility that manages the autoinvoicing feature
Jurisdiction ManagerUtility that generates jurisdiction table from LERG/TMP data sources for US-specific routing
Log RotatorUtility that controls log-files
Mail ManagerSends
e-mails
emails from mail queue (invoices, notifications, etc.)
NotificatorNotifies in case of a low balance or HDD space events
Packages ManagerUtility that manages your packages
Rates GeneratorUtility that generates rates, both manually and automatically
Rates NotificatorUtility that notifies clients about rate changes
Orig-Term Report GeneratorUtility that manages data generation for
reports
Orig-Term report
Reports WatcherUtility that sends generated statistic reports by the scheduled time
Statistics ManagerUtility that manages statistics packages
Traffic Rules ManagerUtility that manages all traffic rules in the system


Panel
borderColor#ffffb3
bgColor#ffffb3
borderWidth2px

(warning)(warning)  Attention

Please note that if a customer had no assigned packets packages, accounts, presets or translations, and you decided to add one, then RADIUS or SIP Redirect servers will notice those changes only after Cache Manager runs and does it's its job. Please note, that this is only applicable if a customer previously had absolutely no items listed above, in other words, if you add a second account to a customer, then that change will be effective instantly.

...

You can always configure the run time of any utility by pressing clicking a respective edit  icon. A pop-up window for utility management has the following structure (see screenshot below):

Screenshot: Utility editing

FieldDescription
Name

Name of the utility

Last Run

Time and date when the last run was initiated

Active
Checkbox. If it's
If this checkbox is marked, the utility is considered active
Run atTo set a periodicity, insert desired values into minute(s), hour(s), and/or day(s) fields and select every or once on the condition for each the
abovementioned
above-mentioned field.
Day of
week
WeekSpecify the days of the week when the
utilty
utility will be run according to the Run at fields values. You can choose either one specific day or all of them (set by default).